This gas water heater detection system (WKGZ-WH56D) adopts a computer centralized distributed measurement and control system. The overall system mainly consists of an industrial control computer, a data acquisition board, and various types of sensors. The data acquisition board collects sensor signals, processes them, and returns them to the industrial control computer. The upper computer software of the industrial control computer is installed to process and calculate the data and implement it.
This gas water heater detection system mainly includes a testing core box, peripheral sensors, angle seat valves or solenoid valves. The peripheral sensors are configured with all relevant sensors except for electromagnetic flow meters and gas flow meters by default. Users can also add electromagnetic flow meters and gas flow meters as needed.
The current model, compared to (WKGZ-WH56CA), also meets the requirements of hardware acquisition and control, including GB6932、EN26、EN13203-2&Regulation 812、 Energy efficiency level testing including 814 (European standard ERP), 10CFR Pt.430 Subpt. B APP. E (American standard), AS5263.1.2 (Australian standard), and some routine testing have been conducted. In addition, WiFi and Bluetooth (with external antenna configuration), 2 sets of RS232 communication interfaces (for expanding the access of flue gas analyzer and programmable power supply), and 1 set of control valve interfaces have been added to the hardware.
Key components
| serial number | name | specification |
| 1 | Gas temperature sensor | Range: 0-100 ℃ Type: PT100 Accuracy: ± 0.1 ℃ Display accuracy: 0.01 ℃ |
| 2 | Gas pressure sensor | Range: 0-7kPa Accuracy: 0.2% FS Display accuracy: 0.01kPa |
| 3 | Primary pressure sensor | Range: 0-7kPa Accuracy: 0.2% FS Display accuracy: 0.01kPa |
| 4 | Secondary pressure sensor | Range: 0-2kPa Accuracy: 0.5% FS Display accuracy: 0.01kPa |
| 5 | Gas pressure regulating valve | 0.5~50mbar |
| 6 | Inlet and outlet water temperature sensor | Range: 0-100 ℃ Type: PT100 Accuracy: ± 0.1 ℃ Display accuracy: 0.01 ℃ |
| 7 | Water outlet temperature sensor | Range: 0-100 ℃ Type: T-shaped Accuracy: ± 0.5 ℃ Display accuracy: 0.01 ℃ |
| 8 | Inlet and outlet water pressure sensor | Range: 0-1.6 MPa Accuracy: 0.5% FS Display accuracy: 0.01MPa |
| 9 | Inlet pressure regulating valve | 0.07~1.7MPa |
| 10 | Atmospheric pressure sensor | Range: 0-210kPa Accuracy: 0.2% FS Display accuracy: 0.01kPa |
| 11 | Environmental temperature and humidity sensor | Range: Humidity: 0-100% Range: Temperature: 0-50 ℃ |
| 12 | Smoke exhaust temperature sensor | Range: 0-450 ℃ Type: T-shaped Accuracy: ± 0.5 ℃ Display accuracy: 0.01 ℃ |
Optional test package
| serial number | name | test item |
| 1 | GB6932-2015 | Thermal efficiency test Heat load test Hot water production rate Hot water stabilization time&water temperature overshoot Stop water and increase temperature heating time |
| 2 | EN26-2015 | Thermal efficiency test Heat load test |
| 3 | 10CFR Pt.430 Subpt.B APP.E(American Standard)-2022 | Maximum GPM testing DOE 24-hour energy efficiency test |
| 4 | AS5263.1.2-2016 | Hot state heat load test Cold state heat load test Start water heating capacity test energy efficiency test |
| 5 | EN13203-2&Regulation 812、814(ERP) | 24-hour energy efficiency test |
| 6 | T/CAQI 263-2022 (Group Standard) | Sine wave test Square wave fluctuation test |